EXTERNAL – TYPE EXCP

EXTERNALY INSTALLED MEASURING DEVICE – FEEDBACK SYSTEM TYPE EXCP

The external feedback system provides a different technical solution

The shift of the control piston is mechanically transmitted to switch box placed on the valve outside on the valve body.

The external feedback system provides a different technical solution which results with reliable function for all HYREVAL® drive combinations, regardless nominal size and pressure, at both normal and hard working condition including different explosive environments.

Feedback system type EXCP provides different combinations:

VC – device for local visual control of valve openness.

VC – device for local visual control of valve openness.

VC & LS – device for local visual control , limit switches mechanical or inductive types

VC & LS & RT device for local visual control , limit switches & rotary or linear transmitter different types (most often 4-20 mA) This feedback system is for unlimited temperature of flow medium, from cryogenic areas to high temperature areas such as hot steam.

EXTERNAL CONTROL OF POSITION – SYSTEM TYPE EXCP

hydromat-system-type-excp